Optical constants

Refractive index of BF11 (LZOS)

BF11: n 0.365–2.325 µm

Data
tabulated n
Range
0.365–2.325 µm
Points
31
Licence
CC0-1.0

Plot

Click the plot to set the calculator wavelength.

At one wavelength

Range 0.365–2.325 µm
Refractive index n
1.6223
Extinction coefficient k
0
Permittivity ε1
2.63187
Permittivity ε2
0
Absorption coefficient α
0 cm⁻¹
Penetration depth δ = λ/(2πk)
— nm
Abbe number Vd
—
Chromatic dispersion dn/dλ
-0.0611057 µm⁻¹
Group index ng
1.65821
Group velocity dispersion
— fs²/mm
Dispersion parameter D
— ps/(nm·km)
Photon energy
2.11001 eV

ε = (n + ik)², α = 4πk/λ, ng = n − λ dn/dλ, GVD = λ³/(2πc²) d²n/dλ², D = −(λ/c) d²n/dλ². Group-velocity dispersion is given for formula data only.

Use it in Lightsmith

Load this data in Python, simulate in one more line

pip install lightsmith
import lightsmith as ls

# BF11 (LZOS): BF11
lzos_bf11 = ls.fetch_refractiveindex("specs", "LZOS-optical", "BF11", ref="c5c2f188e848453def5970e347399d653df2ffc2")
print(lzos_bf11.range_nm)  # (365, 2325.4) nm
eps = lzos_bf11.eps([633])  # complex permittivity

Downloads the original record once (pinned to the imported snapshot) and caches it.

Lightsmith is open source (MIT): Mie, T-matrix, BEM, DDA, FDTD, RCWA, TMM, mode solvers and inverse design behind one spec, on CPU or GPU. GitHub.

References

Cite

LZOS Clear optical glass catalogue; Data from the refractiveindex.info database (M. N. Polyanskiy, Sci. Data 11, 94 (2024), doi:10.1038/s41597-023-02898-2)

Data

31 rows as published
BF11 (LZOS), BF11: n and k versus wavelength
λ (µm)n
0.3651.65181
0.404661.64242
0.435831.636984
0.479991.631167
0.486131.630491
0.4881.63029
0.5141.62774
0.52081.62713
0.531.62635
0.546071.625092
0.56821.62353
0.587561.622305
0.589291.6222
0.63281.61986
0.643851.619339
0.64711.61919
0.656271.618781
0.69431.61724
0.706521.6168
0.76821.61483
0.85211.6127
0.891.61189
1.01391.60967
1.061.60896
1.12861.60797
1.39511.60466
1.52961.6031
1.81311.59977
1.97011.59783
2.24931.59411
2.32541.59302

Optical transmission calculator

Free-standing sample in vacuum, normal incidence
Method
Transmittance T
—
Reflectance R
—

Fresnel reflection calculator

Direction
Rp
—
Rs
—
R = (Rp+Rs)/2
—
Phase φp
—
Phase φs
—
Brewster angle θB
—
Critical angle θC
—