Optical constants

Refractive index of CdSe (Cadmium selenide)

Bond et al. 1965: n(o) 0.80–4.0 µm

Data
tabulated n
Range
0.8–4 µm
Points
18
Optical axis
o
Licence
CC0-1.0

Uniaxial crystal, axes: oe

Plot

Click the plot to set the calculator wavelength.

At one wavelength

Range 0.8–4 µm
Refractive index n
2.47363
Extinction coefficient k
0
Permittivity ε1
6.11885
Permittivity ε2
0
Absorption coefficient α
0 cm⁻¹
Penetration depth δ = λ/(2πk)
— nm
Abbe number Vd
—
Chromatic dispersion dn/dλ
-0.043 µm⁻¹
Group index ng
2.5506
Group velocity dispersion
— fs²/mm
Dispersion parameter D
— ps/(nm·km)
Photon energy
0.692649 eV

ε = (n + ik)², α = 4πk/λ, ng = n − λ dn/dλ, GVD = λ³/(2πc²) d²n/dλ², D = −(λ/c) d²n/dλ². Group-velocity dispersion is given for formula data only.

Use it in Lightsmith

Load this data in Python, simulate in one more line

pip install lightsmith
import lightsmith as ls

# CdSe (Cadmium selenide): Bond et al. 1965: n(o) 0.80–4.0 µm
cdse = ls.fetch_refractiveindex("main", "CdSe", "Bond-o", ref="c5c2f188e848453def5970e347399d653df2ffc2")
print(cdse.range_nm)  # (800, 4000) nm
eps = cdse.eps([1790])  # complex permittivity

Downloads the original record once (pinned to the imported snapshot) and caches it.

Lightsmith is open source (MIT): Mie, T-matrix, BEM, DDA, FDTD, RCWA, TMM, mode solvers and inverse design behind one spec, on CPU or GPU. GitHub.

Comments and conditions

Ordinary ray (o); Room temperature.

Conditions

direction
o

References

W. L. Bond. Measurement of the refractive indices of several crystals. J. Appl. Phys. 36, 1674-1677 (1965)
  • doi:10.1063/1.1703106 Measurement of the Refractive Indices of Several Crystals, Journal of Applied Physics (1965)

Cite

W. L. Bond. Measurement of the Refractive Indices of Several Crystals. Journal of Applied Physics, 36, 1674-1677 (1965), doi:10.1063/1.1703106; Data from the refractiveindex.info database (M. N. Polyanskiy, Sci. Data 11, 94 (2024), doi:10.1038/s41597-023-02898-2)

Data

18 rows as published
CdSe (Cadmium selenide), Bond et al. 1965: n(o) 0.80–4.0 µm: n and k versus wavelength
λ (µm)n
0.82.6448
0.92.5826
1.02.5502
1.22.5132
1.42.4929
1.62.4818
1.82.4732
2.02.4682
2.22.4642
2.42.4612
2.62.459
2.82.4562
3.02.4522
3.22.4532
3.42.4518
3.62.4509
3.82.4498
4.02.4491

Optical transmission calculator

Free-standing sample in vacuum, normal incidence
Method
Transmittance T
—
Reflectance R
—

Fresnel reflection calculator

Direction
Rp
—
Rs
—
R = (Rp+Rs)/2
—
Phase φp
—
Phase φs
—
Brewster angle θB
—
Critical angle θC
—